ICP 1177997 ECM X-13 Blower Motor

ICP 1177997 ECM X-13 Blower Motor
Item# 1177997
$417.94
Availability: Usually ships the same business day

Product Description

ICP 1177997 ECM X-13 Blower Motor

Includes:

  • (1) - ECM X-13 Blower Motor (1177997)

Specifications:

  • Manufacturer: genteq
  • Model # 5SME39HXL127
  • Horsepower: 1/2
  • Voltage: 208/230
  • Hertz: 60
  • Amperage: 4.10
  • RPM: 1200
  • Speeds: 5
  • Phase: Single
  • Frame: 48
  • Rotation: CCW
  • Mounting Type: BAND
  • Shaft Diameter: 1/2"
  • BearingType: BALL
  • Length: 3-59/64"

Note: Always check the blower wheel on your blower assembly. Bad or unbalanced blower wheels can cause premature motor failure due to vibration. If you are not sure what blower wheel fits your blower assembly, call us at 734-326-3900.

Note: The most common cause of ECM motor failure is poorly conditioned power. To protect sensitive ECM modules against transient voltage, power surges, lightning, and voltage spikes, it is highly recommended that you install a Zebra X13PR inline ECM protector.

Replaces Old ICP Part Numbers:

  • There are no older part numbers.

Fits ICP, Heil, Tempstar, Arcoaire, Comfortmaker, Snyder General, KeepRite and Day & Night Models:(Press ctrl + F to find model number below if you have any questions call 734-326-3900 for further information)

PAD324000K000C1, PAD324000KTP0C1, PAD424000K000C1, PAD424000K000D1, PAD424000KTP0C1, PDD324040K000C1, PDD324040K001C1, PDD324060K000C1, PDD324060K001C1, PDD424040K000C1, PDD424040K001C1, PDD424060K000C1, PDD424060K001C1, PDS324040KGP0C1, PDS324040KGP1C1, PDS324060KGP0C1, PDS324060KGP1C1, PDS424040KGP0C1, PDS424040KGP1C1, PDS424060KGP0C1, PDS424060KGP1C1, PGD324040K000C1, PGD324040K001C1, PGD324040KTP0C1, PGD324040KTP1C1, PGD324060K000C1, PGD324060K001C1, PGD324060KTP0C1, PGD324060KTP1C1, PGD424040K000C1, PGD424040K001C1, PGD424040KTP0C1, PGD424040KTP1C1, PGD424060K000C1, PGD424060K001C1, PGD424060KTP0C1, PGD424060KTP1C1, PGS324040KGP0C1, PGS324040KGP1C1, PGS324040KGS0C1, PGS324040KGS1C1, PGS324060KGP0C1, PGS324060KGP1C1, PGS324060KGS0C1, PGS324060KGS1C1, PGS424040KGP0C1, PGS424040KGP1C1, PGS424040KGS0C1, PGS424040KGS1C1, PGS424060KGP0C1, PGS424060KGP1C1, PGS424060KGS0C1, PGS424060KGS1C1, PHD324000K000C1, PHD324000KTP0C1, PHD424000K000D1, PHD424000K000E1, PHD424000KTP0D1, PHD424000KTP0E1, WPA3244000RKC1, WPA4244000RKA1, WPG3244040LKC1, WPG3244040RKC1, WPG3244060LKC1, WPG3244060RKC1, WPH3244000RKC1, WPH4244000RKA1,

What are the symptoms of a ICP ECM (DC) Blower Motor Assembly not working?

Breaker trips. Furnace turns off and does not restart. Motor is seized and cannot turn blower wheel by hand.