# Gas Valves - Furnace Gas Control Valves

Shop replacement gas valves for residential and commercial gas furnaces. We stock natural gas and LP (propane) gas valves, combination gas valves, and two-stage gas valves from all major HVAC brands at our Westland, Michigan warehouse.

## Why Buy Gas Valves From Technical Hot & Cold?

**Complete Valve Selection**
From standard single-stage to modulating gas valves, we stock the valves for all furnace types and brands.

**Genuine OEM Parts**
Gas valves are critical safety components. We sell only genuine manufacturer valves - never aftermarket substitutes for this safety-critical part.

**Expert Valve Identification**
Gas valves have specific voltage, gas type, and pressure requirements. Our team helps ensure you get the exact right valve.

**Same-Day Shipping**
Gas valves in stock ship today when ordered before 3PM EST from our Westland warehouse.

## What is a Gas Valve?

The gas valve is a safety control that:
- Regulates gas flow to burners
- Opens only when safe conditions proven
- Controls gas pressure to burners
- Provides emergency shutoff capability
- Critical safety component in every gas furnace

**Located:** Near the burner assembly
**Function:** Main gas control and safety device

## Types of Gas Valves

### Single-Stage Gas Valves
On/off operation - most common in residential furnaces.

**Features:**
- Simple on/off operation
- Full gas flow when on
- 24V control voltage
- Manual shutoff
- Pressure regulator built-in

**Common Configurations:**
- Natural gas or LP
- 1/2" or 3/4" connections
- Inlet/outlet orientation varies

**Used In:**
- Standard efficiency furnaces
- Single-stage furnaces
- Most residential applications

### Two-Stage Gas Valves
Low and high fire operation for better efficiency.

**Features:**
- Two levels of gas flow
- Low fire (typically 65-70%)
- High fire (100%)
- Better comfort and efficiency
- Quieter operation

**Benefits:**
- Reduced cycling
- More even temperatures
- Lower operating costs
- Extended equipment life

**Used In:**
- Two-stage furnaces
- Premium residential systems
- Some commercial equipment

### Modulating Gas Valves
Variable gas flow for maximum efficiency.

**Features:**
- Continuously variable output
- 40-100% modulation typical
- Precise temperature control
- Maximum efficiency
- Advanced control systems

**Benefits:**
- Best comfort
- Highest efficiency
- Minimal temperature swing
- Quietest operation

**Used In:**
- High-efficiency modulating furnaces
- Premium systems
- Variable-speed systems

### Combination Gas Valves
Integrated pressure regulator and safety shutoff.

**Features:**
- All controls in one body
- Pressure regulator
- Safety shutoff
- Manual valve
- Inlet/outlet connections

**Most Common Type:**
- Honeywell VR8 series
- White-Rodgers 36G/36J series
- Standard on most modern furnaces

### Standing Pilot Gas Valves
For older furnaces with pilot lights.

**Features:**
- Thermocouple safety
- Pilot adjustor
- Manual lighting
- Mechanical operation

**Less Common Now:**
- Being phased out
- Lower efficiency
- Safety concerns
- Replaced by electronic ignition

## Popular Gas Valve Brands

**OEM Manufacturers:**
- **Carrier/Bryant** - OEM gas valves
- **Trane/American Standard** - Gas control valves
- **Lennox** - Furnace gas valves
- **Goodman/Amana** - Gas valves
- **Rheem/Ruud** - Gas control valves

**Valve Manufacturers:**
- **Honeywell** - Industry standard, VR8 series
- **White-Rodgers** - Quality gas valves
- **Johnson Controls** - Commercial valves
- **Robertshaw** - Gas control valves

## Gas Valve Specifications

### Critical Specifications:

1. **Gas Type** - Natural gas or LP (propane)
2. **Voltage** - Usually 24V AC
3. **Pressure Rating** - Inlet and outlet pressures
4. **Connection Size** - 1/2" or 3/4" NPT
5. **Stages** - Single, two-stage, or modulating
6. **Orientation** - Inlet/outlet configuration

### Pressure Specifications:

**Natural Gas:**
- Inlet pressure: 4-7" W.C. (typical)
- Outlet pressure: 3.5" W.C. (common)
- Varies by furnace model

**LP (Propane):**
- Inlet pressure: 11" W.C. (typical)
- Outlet pressure: 10" W.C. (common)
- Different from natural gas!

**⚠️ CRITICAL:** Wrong gas type = dangerous!
- Natural gas valve on LP = incomplete combustion
- LP valve on natural gas = over-firing
- MUST match gas type

## Gas Valve Conversion

### Converting Natural Gas to LP:

**Not Just the Valve:**
- Gas valve must be changed
- Orifices must be changed
- Pressure settings adjusted
- Proper conversion kit required
- Professional installation required

**Or Convert the Valve:**
- Some valves have conversion kits
- Replace spring/regulator
- Adjust pressure settings
- Follow manufacturer procedure

**Safety Note:** Gas conversions should be done by qualified professionals. Improper conversion is dangerous.

## Gas Valve Troubleshooting

### Symptoms of Bad Gas Valve:

**No Gas Flow:**
- Valve clicks but no gas
- Solenoid operates but valve stuck
- Internal failure
- Debris in valve

**Won't Open:**
- No click sound
- No voltage to valve
- Bad coil
- Control board issue

**Gas Leak:**
- Smell of gas at valve
- Hissing sound
- Soap bubble test shows leak
- DANGER - call professional immediately

**Intermittent Operation:**
- Sometimes works, sometimes doesn't
- Valve sticking
- Loose wire connections
- Bad coil

**Low Gas Pressure:**
- Weak flames
- Yellow flames
- Sooting
- Pressure regulator issue

### Diagnostic Steps:

1. **Check for Voltage**
   - Measure 24V at valve when calling for heat
   - No voltage = control problem
   - Has voltage but no click = bad valve

2. **Listen for Click**
   - Valve should click when energized
   - Click but no gas = internal problem
   - No click = bad coil or no voltage

3. **Check Manual Shutoff**
   - Ensure valve is in ON position
   - Must be parallel to pipe

4. **Measure Gas Pressure**
   - Inlet and outlet pressure
   - Compare to specifications
   - Low pressure = problem

5. **Inspect Wiring**
   - Connections tight
   - No damaged wires
   - Proper terminals

## Gas Valve Installation

**⚠️ EXTREME CAUTION REQUIRED**

Gas valve replacement involves working with natural gas or propane. This is dangerous work that should be done by qualified professionals. Improper installation can cause:
- Gas leaks
- Explosions
- Carbon monoxide poisoning
- Death

**If you choose to proceed:**

**Safety First:**
1. Turn off gas supply
2. Turn off all electrical power
3. Ventilate area
4. No smoking or flames
5. Have gas leak detector or soap solution

**Replacement Steps:**

1. **Documentation**
   - Photo all wiring
   - Photo gas piping orientation
   - Note wire colors
   - Record pressure settings

2. **Disconnect Power**
   - Turn off breaker
   - Turn off furnace switch
   - Verify no voltage

3. **Turn Off Gas**
   - Main gas shutoff
   - Appliance shutoff
   - Wait 5 minutes

4. **Disconnect Wires**
   - Label all wires
   - Remove from terminals
   - Keep organized

5. **Disconnect Gas Pipes**
   - Use two wrenches
   - Support piping
   - Catch any residual gas

6. **Remove Old Valve**
   - Remove mounting hardware
   - Extract carefully

7. **Install New Valve**
   - Check orientation
   - Position correctly
   - Secure mounting

8. **Reconnect Gas Pipes**
   - Apply pipe dope or tape (gas-rated)
   - Hand-tighten first
   - Use two wrenches to tighten
   - Don't overtighten

9. **Reconnect Wires**
   - Match wire labels
   - Secure terminals
   - Double-check connections

10. **Leak Test (CRITICAL)**
    - Turn on gas slowly
    - Apply soap solution to all connections
    - Look for bubbles
    - No bubbles = no leaks
    - Any leak = shut off gas, fix immediately

11. **Test Operation**
    - Restore power
    - Call for heat
    - Verify ignition
    - Check flames (blue, steady)
    - Monitor complete cycle

12. **Final Checks**
    - Recheck all connections for leaks
    - Verify proper operation
    - Monitor first several cycles

## Common Installation Mistakes

❌ **Wrong Gas Type**
- Natural gas vs LP
- DANGEROUS if wrong
- Must match exactly

❌ **Improper Piping**
- Wrong thread sealant
- Overtightened connections
- Unsupported piping
- Can cause leaks

❌ **Wiring Errors**
- Wrong terminal connections
- Loose wires
- Reversed polarity
- Prevents operation

❌ **Skipping Leak Test**
- NEVER skip leak testing
- Test every connection
- Use proper method
- Safety critical

❌ **Wrong Pressure Settings**
- Outlet pressure must be correct
- Affects combustion
- Can be dangerous

## Gas Valve Maintenance

**Annual Service:**
- Visual inspection for leaks
- Check wire connections
- Verify proper operation
- Clean burner assembly
- Check gas pressures

**Signs of Problems:**
- Delayed ignition
- Yellow flames
- Sooting
- Gas odor
- Unusual sounds

**Preventive:**
- Annual professional service
- Keep area clean and dry
- Address issues promptly
- Don't ignore problems

## Gas Valve FAQs

**Q: Can I repair a gas valve?**
A: No. Gas valves are not field-serviceable. They must be replaced if faulty.

**Q: How long do gas valves last?**
A: 15-20 years typical. Some last longer, some fail sooner. Depends on usage and conditions.

**Q: What causes gas valves to fail?**
A: Common causes:
- Age/wear
- Electrical surge
- Debris in valve
- Corrosion
- Manufacturing defect

**Q: Can I use a natural gas valve with LP?**
A: NO! Extremely dangerous. Must use correct valve for gas type.

**Q: Why is gas so much at the valve?**
A: Indicates leak. Turn off gas immediately. Call professional. This is an emergency.

**Q: Can I clean a gas valve?**
A: Not recommended. Internal cleaning can damage precision parts. Replace if problems.

**Q: Do gas valves need adjustment?**
A: Outlet pressure may need adjustment during installation. Should be done by qualified technician with proper tools.

**Q: What's the clicking sound?**
A: Normal. Solenoid operating to open valve. If clicking rapidly or continuously, there's a problem.

## When to Call a Professional

**Always call for:**
- Gas leak suspected
- Smell of gas
- Yellow flames
- Sooting or carbon buildup
- Delayed ignition
- If you're unsure

**Gas work is dangerous:**
- Explosions possible
- Carbon monoxide risk
- Death possible
- Use qualified professionals

## Need Help Selecting a Gas Valve?

Our HVAC parts specialists are here to help! Contact us:
- **Phone:** [Your phone number]
- **Email:** [Your email]
- **Hours:** [Your business hours]
- **Location:** Westland, MI - Local pickup available

**⚠️ IMPORTANT: Have your complete furnace model number. Gas valves must be exact matches for safety!**

**⚠️ WARNING: If you smell gas, leave immediately and call your gas company or 911!**