close
close
click to zoom in

Have Questions? Ask a Tech!

  • Genuine OEM Parts

    Offering genuine parts for your specific brand.

  • In-House HVAC Techs

    We help you diagnose, find, and install the part.

  • 1-Year Warranty & Returns

    Failed, or didn't need it? No hassle returns.

  • Expedited Delivery

    Offering competitively-priced expedited shipping.

Deltatherm 003-5103 Chiller

No reviews yet Write a Review

Call for price.

Brand
Deltatherm
SKU:
003-5103
Condition:
New
Weight:
151.00 LBS
  • Technical Hot & Cold BBB Business Review

Deltatherm 003-5103 Chiller

  • Part Info & Specifications

  • Deltatherm 003-5103 Replacement Part

    This item must ship via freight. Please call us at 734-326-3900 to get a shipping quote.

    Includes:

    • (1) - Chiller (003-5103)

    Specifications

    • Basic design features of the RKV .5-DK Series:
    • Ready for connection,tested for functionality and performance units in an air-cooled design for a frost-free indoor installation with a built-in water pump and lines ready for connection.
    • All components necessary for the fully automatic cooling process are included in the industrial coolers.
    • The industrial coolers are manufactured according to DIN EN ISO 9001 (German Institute for Standardization) and the corresponding CE Directives.
    • Housing construction:
    • Base plate made of galvanized sheet steel
    • Cladding plates made of externally varnished sheet steel
    • Easy to remove cladding plates
    • Assembly of the housing components with screw or rivet connections
    • 4 crane eyebolts for easy lifting of the system
    • 4 rollers for easy relocating of the system
    • See article description in Textured Paint for color of the housing cladding plates.
    • Compressor
    • Highly efficient, energy-optimized scroll compressor, hermetic design in the latest generation
    • Suction-gas cooled drive motor
    • Equipped with suction-sided and pressure-sided solder contacts
    • Complete with oil filling Motor protection through thermal or external monitoring module
    • The compressors are mounted on rubber vibration dampers which reduces the transmission of compressor start-up noises and compressor vibrations
    • Through the uniform compression process, the low number of moving components, and an optimized suction gas routing as well as the dispensing of suction and pressure-sided inlet and outlet valves, the compressor achieves a very low noise level with minimal vibration.
    • Condenser
    • Multi-row, highly efficient, high-capacity condensers made of copper pipes with formed aluminum lamellae and a frame made of galvanized sheet steel guarantee an efficient heat transfer Air intake filter made of metal mesh, cleanable
    • Condenser Fan
    • Fan with axial design with induced draught sickle-shaped blades
    • Direct drive through alternating current or 3-phase external rotor motor
    • The fans are statically and dynamically balanced and form an optimally aerodynamic unit with the ventilating fan nozzle
    • The fan blades are made of aluminum injections molding or plastic injection molding
    • Motor protection through thermal monitoring module
    • Maintenance-free and friction-optimized ball bearing
    • External contact protection in accordance with DIN 31001 (German Institute for Standardization)
    • Evaporator
    • Compact, with a copper soldered evaporator made of 1.4401 stainless steel
    • Designed for dry coolant expansion
    • An optimized coolant distribution system in conjunction with a diagonal medium routing ensures a uniform performance of the plate surface
    • The external surfaces of the evaporator are provided with a diffusion-dense and fully cellular, closed cold protection insulation for the reduction of condensate
    • Cooling circuit
    • Cooling design in accordance with EN 378 Standard
    • Conduits made of copper piping in accordance with DIN 8905 (German Institute for Standardization) or completely piped with coolant pipes
    • Completely operational filled with CFC - free coolants
    • Coolant filter dryer with high absorption capacity of moisture
    • Coolant inspection glass
    • Thermo-static expansion valve with MOP
    • Service connections at the high and low pressure sides
    • High pressure switch implemented as a safety pressure limiter
    • Low pressure switch implemented as a pressure controller
    • The coolant system is pressure-tested, checked for leakage, dehumidified, evacuated and is provided with the necessary coolant filling and oil filling
    • The expansion valve is designed for the highest stability in all load ranges with an extended range of application without a decrease in performance. The volumetric compressor efficiency is further increased through an optimized injection and thus an optimal surface utilization of the evaporator. Quick and reliable regulation of the coolant pressure and temperature
    • Media circuit
    • Unit completely piped or hosed internally
    • Externally mounted media connections made of stainless steel
    • Without tank for use at a external tank
    • Medium Pump
    • Control Cabinet
    • Includes all switches and control devices for automatic operation of the industrial cooler
    • Designed in accordance EN 60204, Part 1 (German Institute for Standardization) and VDE 0113, Part 1 with optionally available conductor destination marking CE - Correspondent
    • Main switch in Red/Yellow optional without extra charge and also available in black as a range switch
    • For 3-phase machines with motor protection switch for compressor, fan and pump
    • Terminals to the main power feed
    • A 400 V / 24 V AC transformer for the control circuit serves to supply the control components as well as the electronic regulation with display and operational controls.
    • Safety chain consists of high and low pressure switches, thermal compressors, fan and pump
    • Circuit breaker for control voltage
    • A micro-process controlled temperature controller with digital target and actual display controls and monitors all components of the industrial cooler and regulates the media temperature in dependence of the heat load in the media circuit. For the actual value absorption, a temperature sensor is installed in the media circuit of the industrial cooler.
    • The microprocessor compares the measurement value to an adjustable set value and regulates the media outlet temperature. The operating terminal is easy to operate and configure via keys. The keys have a defined meaning and allow quick access to important set points and system values.
    • Runtime protection for the compressor
    • Potential-free output for collective failure message (24 V of AC, 1A)
    • External ON / OFF
    • Optionally, we offer in addition to the standard design:
    • Installation supports under the machine
    • Air filter mat monitoring
    • Fan with external pressure to the connection with an air duct
    • Split design with internal and external units
    • Water-cooled condenser
    • Variable speed control of the fans
    • Pump overflow valve for pump protection
    • Manometer for display of the water outlet pressure
    • Conductor destination marking
    • Heavy plug connectors (e.g., Harting or comparable)
    • Cold manometer for high and low pressure sides
    • Media outlet temperatures up to +40°C
    • Flow monitors with analogous or digital signal
    • Water filter
    • Shut-off valves in the flow and return
    • Check valves and solenoid valves for the water circuit (load higher than cooler)
    • Tank filling with float valve
    • Automatic water backfeed with float switch
    • Tank heating for tempering
    • Pump disconnection
    • Water circuit made of stainless steel of PVC, e.g. for deionized water
    • Conductance monitoring
    • Multiple circuit system
    • Heat recovery
    • 24 V AC/DC voltage control
    • Potential-free collective failure message
    • External ON/OFF
    • Special voltages and frequencies (50 / 60 hertz)
    • Limit temperature monitoring
    • Temperature difference regulation
    • External temperature sensor
    • Control cabinet heating, control cabinet fan
    • Bus connection, e.g., Profi Bus DP
    • Single fault displays (in clear text display or as a bit technology)
    • Special RAL color according to choice
    • Technische Daten RKV 3.5-S DK with pump without tank
    • technical data RKV 3.5-S DK
    • Kalteleistung bei 15°C
    • Mediumaustrittstemperatur ca. 10900 Watt
    • cooling capacity at 15°C
    • medium out approx.
    • Kalteleistung bei 20°C
    • Mediumaustrittstemperatur ca. 13000 Watt
    • cooling capacity at 20°C
    • medium out approx.
    • Umgebungstemperatur (auslegung) + 32 Grad C
    • ambient temperature (design)
    • Umgebungstemperatur min./max +8 / +42 Grad C
    • ambient temperatur minimum / maximum
    • Umlaufmedium min./max. +8 / +25 Grad C
    • flow medium minimum / maximum
    • Umlaufmedium Emulsion with 7% Oil, CLEAN flow medium
    • Umlaufmenge der Pumpe ca. 60 l/min
    • pump flow approx.
    • Pumpendruck ca. CM 1,5 bar
    • pump pressure approx.
    • Pumpenantriebsleistung 1,3 kW
    • pump drive
    • Mediumanschlusse
    • Vor-und Rucklauf 1 " IG (female)
    • medium connections in/ out
    • Inhalt Mediumtank ca. external, open against atmosphere
    • tank capacity approx.
    • Luftmenge ca. 4500 m3/h
    • air capacity approx.
    • Anzahl Axialventilatoren 1 St.
    • number of fans
    • Antriebsleistung Luftermotor 0, 48 kW
    • fan drive
    • Abmessungen ca. Breite / width 600 mm
    • dimensions Tiefe / length 600 mm
    • Hoho / height 1980 mm
    • Gewicht ca. 180 kg
    • wight approx.
    • Farbe RAL 7012 mittelstruktur halbglanzend
    • color
    • Material im Mediumkreislauf: Edelstahl, Gummi, Stahl parts inthe medium circuit: stainless steel, rubber, steel
    • ElektroanschluB
    • electric connection 480V +/ -5% 60Hz (L1 L2 L3 PE)
    • Steuersoannung 24V +/-5% AC
    • control voltage
    • Temperaturregelung Setpoint
    • temperature control
    • Kaltemittel R 407C
    • refrigerant
    • Bedienanleitung deutsh oder englisch
    • user manual german or English
    • Switch contact via a relais with motor protection relais for a external heater with 4,5kW heating capacity.
    • Harting connector

    Replaces Old Deltatherm Part Numbers

    • There are no older part numbers.

    Fits Models:

    (Press ctrl + F to find model number below.)

    Various. (Call 734-326-3900 with your model and serial number for more information.)

Worldwide Shipping
Genuine OEM Parts
Secure Shopping
1-Year Returns