Goodman Amana PCBBF124S Replacement Part
Note: The use of the PCBBF107 board in this kit with an 80 volt ignitor will result in ignitor failure! When using this kit to replace a board on the 80 volt system, the hot surface ignitor included in this kit must also be used.
Includes:
- (1) - Hot Surface Ignition Control (PCBBF107)
- (3) - Wiring Harness
- (1) - Ignitor (0130F00008S)
- (1) - Installation Instructions (IO-753)
- (1) - Diagnostic Flash Code Chart (5001-2614)
Specifications
- Manufacturer: White-Rodgers
- Two-Stage
- Board Dimensions: 8 1 /8" x 5 1/4"
- Electrical Ratings -
- Input Voltage:25 VAC, 60 Hz (Class II Transformer Required)
- Max Input Current @ 25 VAC: 500mA + MV
- Relay Load Ratings:
- Gas Valve Relays: 1.5 Amps @ 25 VAC, 60 Hz, 0.6 pf
- Inducer Relays: 2.2 FLA - 3.5 LRA @ 120 VAC
- Ignitor Relays: 4.0 Amp @ 120 VAC, 60 Hz (Resistive)
- Flame Current Requirements:
- Minimum current to insure flame detection: 0.3 ua DC
- Maximum current for non-detection: 0.1 ua DC
- Maximum allowable leakage resistance: 100 M ohms
- Operating Temperature Range: -40 - 175 Degrees Fahrenheit
- Humidity Range: 5% to 93% relative humidity (non-condensing)
- Timing Specs @ 60 Hz
- Flame Establishing Time: 0.8 sec
- Flame Failure Response Time: 2.0 Sec
- Gases Approved: Natural, Manufactured, Mixed, Liquified Petroleum, and LP Gas Air Mixture
- Ignitor Length: 3/4"
Note: To prevent early failure of your new hot surface ignitor, handle by the ceramic base only and avoid contact with the silicon surface. Oils from the skin interact with the material and can cause premature failure.
Replaces Old Goodman Amana Part Numbers
- PCBBF121S
Other Part Numbers
Emerson Climate Technologies, 4893D, 11512410201056, 0130F, 000081447
Fits Goodman, Amana, Daikin, Janitrol, Kenmore, McQuay, Xenon, GMC, and Gree Models:
(Press ctrl + F to find model number below.)
Various. (Call 734-326-3900 with your model and serial number for more information.)