BKW B400095515 Replacement Part
Includes:
- (1) - Motor Protection Switch (B400095515)
Specifications
- Manufacturer: Siemens
- Model # 3RV2021-1CA10
- General technical data
- Size of the circuit-breaker S0
- Size of contactor can be combined company-specific S00, S0
- Product extension
- ● Auxiliary switch Yes
- Power loss [W] total typical 6 W
- Surge voltage resistance rated value 6 kV
- maximum permissible voltage for safe isolation
- ● in networks with grounded star point between
- main and auxiliary circuit
- 400 V
- ● in networks with grounded star point between
- main and auxiliary circuit
- 400 V
- Protection class IP
- ● on the front IP20
- ● of the terminal IP20
- Shock resistance
- ● acc. to IEC 60068-2-27 25g / 11 ms
- Mechanical service life (switching cycles)
- ● of the main contacts typical 100 000
- ● of auxiliary contacts typical 100 000
- Electrical endurance (switching cycles)
- ● typical 100 000
- Certificate of suitability
- ● according to ATEX directive 2014/34/EU DMT 02 ATEX F 001
- ● ATEX Yes
- Protection against electrical shock finger-safe
- Reference code acc. to DIN EN 81346-2 Q
- Ambient conditions
- Installation altitude at height above sea level
- ● maximum 2 000 m
- Temperature compensation -20 ... +60 °C
- Relative humidity during operation 10 ... 95 %
- Main circuit
- Number of poles for main current circuit 3
- Adjustable pick-up value current of the currentdependent
- overload release
- 1.8 ... 2.5 A
- Operating voltage
- ● rated value 690 V
- ● at AC-3 rated value maximum 690 V
- Operating frequency rated value 50 ... 60 Hz
- Operating current rated value 2.5 A
- Operating current
- ● at AC-3
- — at 400 V rated value 2.5 A
- Operating power
- ● at AC-3
- — at 230 V rated value 370 W
- — at 400 V rated value 750 W
- — at 500 V rated value 1 100 W
- — at 690 V rated value 1 500 W
- Operating frequency
- ● at AC-3 maximum 15 1/h
- Auxiliary circuit
- Number of NC contacts for auxiliary contacts 0
- Number of NO contacts for auxiliary contacts 0
- Number of CO contacts
- ● for auxiliary contacts 0
- Product function
- ● Ground fault detection No
- ● Phase failure detection Yes
- Trip class CLASS 10
- Design of the overload release thermal
- Operational short-circuit current breaking capacity
- (Ics) at AC
- ● at 240 V rated value 100 kA
- ● at 400 V rated value 100 kA
- ● at 500 V rated value 100 kA
- ● at 690 V rated value 10 kA
- Maximum short-circuit current breaking capacity (Icu)
- ● at AC at 240 V rated value 100 kA
- ● at AC at 400 V rated value 100 kA
- ● at AC at 500 V rated value 100 kA
- ● at AC at 690 V rated value 10 kA
- Breaking capacity short-circuit current (Icn)
- ● at 1 current path at DC at 150 V rated value 10 kA
- ● with 2 current paths in series at DC at 300 V
- rated value
- 10 kA
- ● with 3 current paths in series at DC at 450 V
- rated value
- 10 kA
- Response value current
- ● of instantaneous short-circuit trip unit 33 A
- UL/CSA ratings
- Full-load current (FLA) for three-phase AC motor
- ● at 480 V rated value 2.5 A
- ● at 600 V rated value 2.5 A
- Yielded mechanical performance [hp]
- ● for single-phase AC motor
- — at 230 V rated value 0.167 hp
- ● for three-phase AC motor
- — at 200/208 V rated value 0.5 hp
- — at 220/230 V rated value 0.5 hp
- — at 460/480 V rated value 1 hp
- — at 575/600 V rated value 1.5 hp
- Short-circuit protection
- Product function Short circuit protection Yes
- Design of the short-circuit trip magnetic
- Mounting position any
- Mounting type screw and snap-on mounting onto 35 mm standard mounting rail
- according to DIN EN 60715
- Height 97 mm
- Width 45 mm
- Depth 97 mm
Country of Origin: Germany
Replaces Old BKW Part Numbers
- There are no older part numbers.
Other Part Numbers
SIEMENS, 3RV2021-1CA10, Sirius, B400095515, G/181214, *E02*, DMT02 ATEX F 001,
Fits Models:
(Press ctrl + F to find model number below.)
Various. (Call 734-326-3900 with your model and serial number for more information.)