Lahntechnik Duotemp 112405 Circuit Breaker

No reviews yet Write a Review

Call for price.

Brand
Lahntechnik Duotemp
SKU:
112405
Condition:
New
Weight:
5.00 LBS
  • Technical Hot & Cold BBB Business Review

Lahntechnik Duotemp 112405 Circuit Breaker

  • Part Info & Specifications

  • Lahntechnik Duotemp 112405 Replacement Part

    CALL (734) 326-3900 or SEND MESSAGE TO PARTS@TECHNICALHOTANDCOLD.COM FOR PRICE!

    Includes:

    • (1) - Circuit Breaker (112405)

    Specifications

    • Manufacturer: Siemens
    • Model # 3RV2011-1CA20
    • Type: 3RV2
    • Size: S00
    • Auxiliary switch Yes
    • Power loss [W] total typical 6 W
    • Insulation voltage with degree of pollution 3 rated
    • value
    • 690 V
    • Surge voltage resistance rated value 6 kV
    • maximum permissible voltage for safe isolation
    • in networks with grounded star point between
    • main and auxiliary circuit
    • 400 V
    • in networks with grounded star point between
    • main and auxiliary circuit
    • 400 V
    • Protection class IP
    • 3RV2011-1CA20 Subject to change without notice
    • Page 1/
    • 9
    • 06/04/20
    • on the front IP20
    • of the terminal IP20
    • Shock resistance
    • acc. to IEC 60068-2-27 25g / 11 ms
    • Mechanical service life (switching cycles)
    • of the main contacts typical 100 000
    • of auxiliary contacts typical 100 000
    • Electrical endurance (switching cycles)
    • typical 100 000
    • Certificate of suitability ATEX Yes
    • Protection against electrical shock finger-safe
    • Reference code acc. to DIN EN 81346-2 Q
    • Ambient conditions
    • Installation altitude at height above sea level
    • maximum 2 000 m
    • Temperature compensation -20 ... +60 °C
    • Relative humidity during operation 10 ... 95 %
    • Main circuit
    • Number of poles for main current circuit 3
    • Adjustable pick-up value current of the currentdependent overload release
    • 1.8 ... 2.5 A
    • Operating voltage
    • rated value 690 V
    • at AC-3 rated value maximum 690 V
    • Operating frequency rated value 50 ... 60 Hz
    • Operating current rated value 2.5 A
    • Operating current
    • at AC-3
    • — at 400 V rated value 2.5 A
    • Operating power
    • at AC-3
    • — at 230 V rated value 370 W
    • — at 400 V rated value 750 W
    • — at 500 V rated value 1 100 W
    • — at 690 V rated value 1 500 W
    • Operating frequency
    • at AC-3 maximum 15 1/h
    • Auxiliary circuit
    • Number of NC contacts for auxiliary contacts 0
    • Number of NO contacts for auxiliary contacts 0
    • Number of CO contacts
    • 3RV2011-1CA20 Subject to change without notice
    • Page 2/
    • 9
    • 06/04/2019 © Copyright Siemens
    • for auxiliary contacts 0
    • Protective and monitoring functions
    • Product function
    • Ground fault detection No
    • Phase failure detection Yes
    • Trip class CLASS 10
    • Design of the overload release thermal
    • Operational short-circuit current breaking capacity
    • (Ics) at AC
    • at 240 V rated value 100 kA
    • at 400 V rated value 100 kA
    • at 500 V rated value 100 kA
    • at 690 V rated value 10 kA
    • Maximum short-circuit current breaking capacity (Icu)
    • at AC at 240 V rated value 100 kA
    • at AC at 400 V rated value 100 kA
    • at AC at 500 V rated value 100 kA
    • at AC at 690 V rated value 10 kA
    • Breaking capacity short-circuit current (Icn)
    • at 1 current path at DC at 150 V rated value 10 kA
    • with 2 current paths in series at DC at 300 V
    • rated value
    • 10 kA
    • with 3 current paths in series at DC at 450 V
    • rated value
    • 10 kA
    • Response value current
    • of instantaneous short-circuit trip unit 33 A
    • UL/CSA ratings
    • Full-load current (FLA) for three-phase AC motor
    • at 480 V rated value 2.5 A
    • at 600 V rated value 2.5 A
    • Yielded mechanical performance [hp]
    • for single-phase AC motor
    • — at 230 V rated value 0.167 hp
    • for three-phase AC motor
    • — at 200/208 V rated value 0.5 hp
    • — at 220/230 V rated value 0.5 hp
    • — at 460/480 V rated value 1 hp
    • — at 575/600 V rated value 1.5 hp
    • Short-circuit protection
    • Product function Short circuit protection Yes
    • Design of the short-circuit trip magnetic
    • 3RV2011-1CA20 Subject to change without notice
    • Page 3/
    • 9
    • 06/04/2019 © Copyright Siemens
    • Design of the fuse link for IT network for short-circuit
    • protection of the main circuit
    • at 400 V gL/gG 25 A
    • at 500 V gL/gG 25 A
    • at 690 V gL/gG 20 A
    • Installation/ mounting/ dimensions
    • Mounting position any
    • Mounting type screw and snap-on mounting onto 35 mm standard mounting rail
    • according to DIN EN 60715

    Country of Origin: Germany

    Replaces Old Lahntechnik Duotemp Part Numbers

    • There are no older part numbers.

    Other Part Numbers

    3RV2011-1CA20, Siemens, Sirius, G/190415, *E02*, HW05014-18042, 02-3450-7110, Lahntechnik, DMT 02 ATEX F 001

    Fits Models:

    (Press ctrl + F to find model number below.)

    Various. (Call 734-326-3900 with your model and serial number for more information.)

Worldwide Shipping